HIGHLIGHTS

ERP
3 Stage Combustion System
Reflectors
Heat Shield
Wind Protection CC
German-Made Ceramic Plates
Technical Specifications
Product Images
Working Principle

Three-Stage Combustion System:
Goldsun CC heaters feature a three-stage combustion system, ensuring the desired comfort level is achieved seamlessly. Depending on the ambient temperature, heating can be adjusted to low, medium, or high levels, providing warmth without discomfort.

Wind Resistance (CC Series):
The protected structure of Goldsun CC heaters prevents them from being extinguished by the wind. High-temperature-resistant special grilles placed in front of the ceramic plates and flame-sensing electrodes at both ends of the device ensure continuous combustion even in windy conditions.

German-Made Ceramic Plates:
Goldsun Performa heaters use German-made, patented ceramic burner plates. These plates, which offer the highest combustion and radiation efficiency in the market, are equipped with stainless steel grilles that increase device efficiency by 20%.

Reflector:
Unlike many products on the market, the reflector is a key element that enhances the performance of Goldsun Performa heaters. It focuses the emitted energy, directing it toward customers rather than dispersing into the air.

Remote Control:
A built-in remote-control module is included, allowing the control of up to 15 devices with a single remote.

Advantages

Goldsun Ceramic Plate and Competitor Product Efficiency Comparison Report

1. Objective: The purpose of this report is to compare the efficiency and fuel savings of our Goldsun brand products with the best-selling competitor product on the market.

2. Methodology: The efficiency of our Goldsun 7/11 model was measured against a competitor product using an Elvhis Radiometer. The radiant efficiency of both products was determined, and their energy consumption per kW was calculated. Additionally, the measured kW/m² values were converted into temperature increase (ΔT) graphs, providing a visual representation of the perceived temperature increase for each device.

3. Measurement Results:
a. Goldsun CC 7/11:

At a 2-meter distance, the perceived temperature increase (ΔT) created by the heater in the environment is illustrated in the graph below. The maximum temperature increase in the effective heating area was measured as 8.24°C.

Measurement Parameters and Results:

Ambient Temperature: 17.3°C
Humidity: 68%
Gas Consumption: 1.12 m³/h
Air Pressure: 1003 hPa
Radiant Factor Measurement Result: 60.19%

b. Competitor Product


At a 2-meter distance, the perceived temperature increase (ΔT) created by the competitor heater is illustrated in the graph below. The maximum temperature increase in the effective heating area was measured as 5.39°C.

Measurement Parameters and Results:
Ambient Temperature: 19°C
Humidity: 59%
Gas Consumption: 1.13 m³/h
Air Pressure: 1004 hPa

Radiant Factor Measurement Result: 44.67%

Areas of Use

Cafes and Restaurants
Industrial Facilities
Open or Semi-Open Areas
Under Umbrellas
Under Pergolas
Balconies and Terraces